withlight

  • HOME
  • KOREAN
  • bullettitle

    • OPI-370LED GONIOMETER SYSTEM

      OPI-370 LED Mirror Goniometer System is for measuring absolute luminous flux of LED device and various LED
      Mirror Goniometer System
    • ¤ýLuminous intensity : total luminous flux, total radiant flux, lumi-nous distribution
      ¤ýSpectral characteristics : Peak wavelength, medium wavelength, CIE1931/1976 color coordinate, color punity, Correlated
         color temperature and Color rendering index
      ¤ýluminous distribution : 1D value for luminous intensity by angle, 2D contour oine for luminous intensity, 3D profile
      ¤ýMax. sample size : 1,500mm x 1,500mm
      ¤ýMax. sample weight: 80kg.
    • opi-310
    • Items
      OPI-300
      OPI-310
      OPI-370
      Automated horizontal range(¥È)
      -135¢ª ~ +135¢ª
      -180¢ª ~ +180¢ª
      Minimum horizontal
      angle resolution
      0.3¢ª
      Minimum axial range(¥Õ)
      0¢ª ~ 360 ¢ª
      Minimum axial angle resolution
      0.1¢ª
      Computer interface
      RS232
      Max. Measuring
      distance
      316mm
      30m
      Dimensions
      567mmX327mmX260mm(Small)
      730mmX524mmX380mm(Medium)
      1000mmX1000mmX1920mm
      2000mmX2670mmX3063mm
      Enclosure
      lightproof enclosure
      Scan time
      Within 20 seconds
      Range of wavelength
      Visible(Option UV/IR)
      Sensor
      V(¥ë) Filter Si Photo diode
      Sensing hole size
      100 mm2
      Range of Current
      0 ~200 mA(Option 0~1A)
      100A
      Power requirements
      220V, 50/60Hz